Process instrumentation
Tank level, pressure and flow sensor interfacing.
Industrial 4–20mA signal generator and reader design, sensor interfacing, calibration and monitoring systems.
Industrial 4–20mA current-loop design — signal generation, loop reading, sensor interfacing and calibration for process instrumentation and plant monitoring.
Precision current-loop ICs, isolated signal-conditioning components, and STM32/ESP32-based readout and logging.
Confirm what's being measured and the existing loop setup.
Design the generator, reader or conditioning circuit.
Calibrate the circuit against known reference values.
Integrate with the existing controller and hand over documentation.
Every circuit is calibrated against known reference values across its full expected range, not just at one point, since a loop that reads correctly at mid-scale can still be off at the extremes. Isolation and noise immunity are checked before the circuit goes anywhere near a live plant floor, and the final calibration is documented so it can be checked again later without starting from scratch.
Tank level, pressure and flow sensor interfacing.
Signal generators for simulating sensors during commissioning.
Reliable loop reading integrated into a wider automation system.
The controller this signal feeds into.
The board carrying the signal-conditioning circuit.
Firmware reading and logging the loop signal.
Want more background first? Read 4-20mA Signal Generator and Reader Systems.
If a 4-20mA loop needs to interface with a modern controller, or an existing circuit needs correcting rather than replacing, we can design the circuit, calibrate it and integrate it with your automation system as one project. Scope, deliverables, schedule and quotation are confirmed once we know what's being measured and what's wrong (or missing) in the current setup. We work with clients internationally and collaborate remotely as standard practice.
See also: Portfolio · Industrial Automation Systems · Contact
Yes, reviewing and correcting an existing circuit — including recalibrating it against known reference values — is common work, not just new designs.
Yes, where the plant already uses RS-485/Modbus for monitoring, we can add that digital interface alongside the 4-20mA loop.
Yes, a 4-20mA signal generator that simulates a real sensor is a common commissioning and testing tool we build.
Yes, isolated signal conditioning is the default approach for this work, since unisolated circuits are far more prone to noise-induced reading errors on a plant floor.
Tell us what's being measured and what's wrong with the current setup.